Specifications
Power Consumption 3.5 watts maximum (2.75 watts at 24
VDC)
Output Relays
• Smoke alarm relay, Form C, 5 amperes at 30 VDC. The
smoke alarm relay has normally open/normally closed contacts and normally de-energized operation.
• Fault relay, Form A, 5 amperes at 30 VDC.The fault relay
has normally open contacts and normally energized operation.
• Auxiliary relay, Form C, 5 amperes at 30 VDC. The auxiliary
relay has normally open/normally closed contacts and normally de-energized operation.
Temperature Range
• Operating: –20°C to 65°C (–4°F to 149°F)
• Storage: –55°C to 70°C (–67°F to 158°F)
Humidity Range 5 to 95% relative humidity.
Ingress Protection IP44 (Applicable to ceiling mount only).
Current Output 0-20 mA (±0.3 mA) DC current, with maximum loop resistance of 300 ohms from 12-17.9 VDC, 500
ohms from 18 to 19.9 VDC, and 600 ohms from 20-30 VDC.
Terminals UL/CSA rated for 14-18 AWG or 2.5-0.75 mm2
wire.
Thread Options 3/4 inch NPT or M25. Multi-port models available.
Enclosure Material Polycarbonate / ABS – Smoke Detector.
Copper-free aluminum (painted) – Junction Box.
Shipping Weight (Approximate) 7.85 lbs (3.56 kg).
Warranty Period 1 year.

Category:

Description

MAGNA 40-6018 EXPLOSION PROOF SMOKE DETECTOR
DOWNLOAD DATASHEET
The 40-6018 Explosion Proof Smoke Detector has Division
and Zone explosion-proof ratings and is suitable for industrial
and commercial applications. The detector is designed to
operate effectively with smoldering and rapidly growing fires
and contains the ability to annunciate fault ensuring no undisclosed failures. The 40-6018 Smoke Detector outputs include
0-20 mA, a localized LED, and relays.
Features
• IECEx Zone approved
• Trouble-free photoelectric operation
• 0-20 mA output for DCS integration
• Self-checking circuitry ensures reliable smoke detection
• Alarm, Auxiliary and Fault relays for controlling annunciating devices or fire panel interface
• LED provides a visual indication that an alarm has occurred
• IP44 ingress protection level suitable for onshore or offshore requirements
• Ideally suited for classified areas in the petrochemical, oil
and gas industry
• DCS, PLC, integration with milliamp or relay outputs
• Rugged design for environmental extremes
• Visual confirmation of detector alarm
• Detects smoldering fires
• No undisclosed failures
Applications
• Combustible storage facilities
• Munitions manufacturing
• Volatile chemical storage
• Chemical processing plants
• Petroleum refineries
• Turbine enclosures
• Battery rooms
• HVAC applications
The hot-swappable sensor module is intrinsically safe and
allows live maintenance while under power, without de-classifying the hazardous area. The integrated junction box is available in a variety of port configurations for simplified wiring and
installation.
Certifications
FM Approved
• Class 1 Div 1 Groups B, C. D T4
• Class 1 Div 2 Groups A, B, C, D, T4
• Class 1 Zone1 AWX db ia llC T4 Gb
IEC/IECx
• FMG 15.0014X
• Ex db ia llC T4 Gb